Support > FAQs > Synergy SKY Sensors

Synergy SKY Sensors

Introduction

This article contains frequently asked questions about our motion detection sensors.

 

Questions and Answers

Question Answer
Where to place the sensor?


Can it be placed in the ceiling?


What area does the sensor cover?
The sensor covers approx. 90-degree angle. The placement is dependent upon the size of the room, but generally we recommend the following:


- For larger rooms, mount it on the wall

- For small huddle rooms, it can be mounted in the ceiling

- The bigger the room is, the less accurate it will be, and you should consider adding two or more sensors to the room.

mceclip0.png
Sensor data sheet can be found here.
How far can the gateway be from sensor? The placement of the gateway depends on how many floors it should cover and the building material.


Our sensors and gateways are based on the LoRaWan standard (https://en.wikipedia.org/wiki/LoRa and the theoretical range is 10+ km in perfect conditions. However, indoor range is dependent upon a number of factors like building material, number of floors, walls, surroundings etc.

Based on our best practices, we will help you find the optimal configuration.

Multiple gateways per installation are supported for redundancy purposes.
How long does the battery last?



How are batteries being replaced?
The life time of the battery depends heavily on signal strenght - the weaker the signal is, the more power is being used by the sensor.
If sensors and gateways are configured and placed according to our recommendations, the theoretical battery life time is estimated to be between 5 and 10 years. However, to be on the safe side, you should expect a battery life time of 3+ years.

You can also test our hardware vendor's
battery life calculator.

The sensor runs on two batteries that can easily be replaced. The battery specifications are:

Li/SOCl2 AA battery
Nominal Voltage: 3.6V
Nominal Capacity: 2700mAh
Standard Discharge Current: 2mA
Operating Temperature (℃): -60℃ to +85℃
Dimensions: 14.5mm
Height: 50.5mm
Weight: 19g



Troubleshooting

Symptom Troubleshooting steps
The gateway does not send data
Make sure that the gateway is reachable. In the sensor administration page, go to Status and toggle ping on:


mceclip0.png
mceclip0.png


Regardless whether it responds to ping request, the customer's network might have firewall rules preventing sensor data to be transferred. Try to connect the gateway to a 4G router or a non-local network to see if that helps.
Sensor data is not received Sensor will need to be provisioned in order to start sending data. If a sensor doesn't send data, please follow these troubleshooting steps:


1. Open the sensor, pull the batteries out and place them back the wrong way to ensure that the built-in capacitor is emptied for power (the sensor will reboots)


2. Place the batteries correctly back in the sensor, check that the LED flashes red once, then orange while the sensor is connecting to the LoRaWan network, when connected it enters its duty cycle and flashes green every time it sends data


3. Check the gateway's LoRaWan tab during the sensor boot procedure and make sure it shows data traffic:


mceclip1.png

Still in need of help?

Create a ticket